Schneider Electric Altivar 320 frequency converter 1.5 kW 380–500 V ATV320U15N4C
Цей частотний перетворювач Altivar 320 може живити трифазні синхронні та асинхронні двигуни. Його компактний тип виконання дозволяє вертикально розміщ...
Тип напруги
Змінний струм
Глибина вбудовування
70 mm
Характеристика спрацьовування
B
Номінальний струм
16 A
Номінальна напруга
400 V
Ступінь захисту IP
IP20
Під`єднуваний переріз багатодротового провідника
1-25 mm²
Клас обмеження струму
3
Code: MBN116
Modular Hager MBN116 miniature circuit breaker with 1 protected pole, B tripping characteristic, 16 A rated current, 400 V AC, 6 kA breaking capacity, IP20 protection, and built-in mounting.
262.08 ₴
On Order
Delivery across Ukraine within 5 days from the purchase date.
Pay for orders via Liqpay and plata by mono services.
100% certified products. Service and support.
Hager MBN116 is a miniature circuit breaker designed to protect electrical circuits in residential, commercial, and other low-voltage installations against overload and short circuit. It is intended for AC networks with a frequency of 50–60 Hz and operates at a nominal voltage of 400 V. The device has one protected pole and a nominal current of 16 A, making it suitable for lighting circuits and socket groups with moderate inrush currents. The B tripping characteristic is typically used where fast response is required for circuits with relatively low starting currents.
The breaker is designed for built-in mounting on a DIN rail and occupies 1 module of width. Its installation depth is 70 mm, which should be taken into account when planning the switchboard layout and selecting the enclosure. The IP20 protection degree indicates indoor use inside electrical panels, where the device is installed in a protected environment after assembly. The operating ambient temperature range from -25 to 70 °C allows use in a wide range of standard indoor electrical conditions.
In terms of switching performance, the device has a rated breaking capacity Icn of 6 kA according to EN 60898 at 230 V and a rated breaking capacity Icu of 6 kA according to IEC 60947-2 at 230 V. These values are important when assessing the breaker’s ability to disconnect fault currents in emergency situations. The current limiting class 3 helps reduce the energy let through during a short circuit, supporting the protection of downstream conductors and connected loads. The rated insulation voltage Ui is 500 V, and the impulse withstand voltage Uimp is 4 kV, which confirms suitability for circuits with the corresponding insulation and surge requirements.
Connection is possible for solid conductors with a cross-section of 1–35 mm² and stranded conductors of 1–25 mm². The device has pollution degree 2 and overvoltage category 3. It does not have a neutral pole switching function, does not support additional accessories, and is not explosion-proof. Power loss is 2.44 W.
Тип напруги
Змінний струм
Глибина вбудовування
70 mm
Характеристика спрацьовування
B
Номінальний струм
16 A
Номінальна напруга
400 V
Ступінь захисту IP
IP20
Під`єднуваний переріз багатодротового провідника
1-25 mm²
Клас обмеження струму
3
Кількість полюсів (загалом)
1
Ширина в кількості модульних відстаней
1
Вибухозахищений
ні
Одночасне перемикання нульового провідника
ні
Можливе додаткове обладнання
ні
Вбудований монтаж
так
Номінальна відмикальна здатність Icn згідно EN 60898 при 230 В
6 kA
Номінальна ізоляційна напруга Ui
500 V
Номінальна відмикальна здатність Icu згідно IEC 60947-2 при 230 В
6 kA
Power loss
2.44 W
Номінальна напруга витримування удару Uimp
4 kV
Під`єднуваний переріз твердого провідника
1-35 mm²
Температура навколишнього середовища під час роботи
-25-70 °C
Частота
50-60 Hz
0 reviews
No reviews for this product yet. Be the first!